Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 5.699
Filtrar
1.
Heliyon ; 10(6): e28206, 2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38560676

RESUMO

Localised treatment of vaginal candidiasis could improve the therapeutic outcomes of patients with vaginal candidiasis as well as reduce drug dosage and dosing interval. The aim of the research project was to develop fluconazole emulgel formulations, and evaluate their physicochemical, drug release, antifungal, safety, and stability profile, for potential treatment of vaginal candidiasis. Xanthan gum and HPMC E5LV-based fluconazole emulgels were prepared using the spontaneous emulsification method and their physicochemical properties, drug content, drug release profile, anti-fungal activity against Candida albicans, in vivo vaginal biocompatibility and stability profile were evaluated using standard protocols. The fluconazole emulgels exhibited satisfactory properties: pH: 5.2-5.4; spreadability: 1.6-2.5 cm; apparent viscosity: 85-314 cP; zone of inhibition against Candida albicans: 22-38 mm; drug content: 91-102 %, and vaginal biocompatibility. All the studied fluconazole emulgels exhibited controlled fluconazole release over 6 h and their drug release kinetics fitted well with Korsmeyer-Peppas model. HPMC-based emulgels exhibited unsatisfactory real-time stability profile. To our knowledge, this is the first report where xanthan gum and HPMC E5LV-based fluconazole emulgels have been studied for possible treatment of vaginal candidiasis. Xanthan gum-based fluconazole emulgels are promising drug formulations that could reduce the drug dosage and dosing frequency. In addition, they could serve as alternative dosage forms to Flucos® gel.

2.
ADMET DMPK ; 12(1): 177-192, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38560712

RESUMO

Background and purpose: Many sectors use nanoparticles and dispose of them in the aquatic environment without deciding the fate of these particles. Experimental approach: To identify a benign species of nanoparticles which can cause minimum harm to the aquatic environment, a comparative study was done with chemically synthesized silver nanoparticles (AgNPs) and green tea mediated synthesis (GT/AgNP) in both in vitro using human alveolar cancer cell line (A549) and normal cell line (L132), and in in vivo with zebrafish embryos. Key results: The in vitro studies revealed that GT/AgNPs were less toxic to normal cells than cancer cells. The GT/AgNPs showed high biocompatibility for zebrafish embryos monitored microscopically for their developmental stages and by cumulative hatchability studies. The reduced hatchability found in the AgNPs-treated group was correlated by differential gene expression of zebrafish hatching enzymes (ZHE) (ZHE1 and ZHE2). Conclusion: The results indicated that nanoparticles can affect the hatching of zebrafish embryos and elicit toxicity at the gene level.

3.
ACS Sens ; 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38563358

RESUMO

The development of advanced technologies for the fabrication of functional nanomaterials, nanostructures, and devices has facilitated the development of biosensors for analyses. Two-dimensional (2D) nanomaterials, with unique hierarchical structures, a high surface area, and the ability to be functionalized for target detection at the surface, exhibit high potential for biosensing applications. The electronic properties, mechanical flexibility, and optical, electrochemical, and physical properties of 2D nanomaterials can be easily modulated, enabling the construction of biosensing platforms for the detection of various analytes with targeted recognition, sensitivity, and selectivity. This review provides an overview of the recent advances in 2D nanomaterials and nanostructures used for biosensor and wearable-sensor development for healthcare and health-monitoring applications. Finally, the advantages of 2D-nanomaterial-based devices and several challenges in their optimal operation have been discussed to facilitate the development of smart high-performance biosensors in the future.

4.
Free Radic Res ; : 1-23, 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38563404

RESUMO

Microwave (MW) radiations are widely used in communications, radar and medical treatment and thus human exposure to MW radiations have increased tremendously, raising health concerns as MW has been implicated in induction of oxidative stress condition in our body. Few metallic nanoparticles (NPs) have been shown to mimic the activity of antioxidant enzymes and hence can be applied for the modulation of adverse effects caused by MW. Present study aimed to assess the biocompatibility of Bovine serum albumin (BSA) conjugated manganese dioxide nanoparticles (MNP*) and to counteract the impact of MW on the haematological system of male Wistar rats. Experiments were conducted in two sets. Set I involved biodistribution and antioxidant activity evaluation of MNP* at different doses. Results showed a dose-dependent increase in antioxidant potential and significant biodistribution in the liver, spleen, kidney, and testis, with no organ damage, indicating its biocompatibility. Experiment set II constituted the study of separate and combined effects of MW and MNP* on haematological parameters, oxidative status, and genotoxic study in the blood of rats. MW exposure significantly altered red blood cell count, hemoglobin, packed cell volume percentage, monocyte percentage, aspartate aminotransferase, Alanine aminotransferase and uric acid. MW also induced significant DNA damage in the blood. A significant increase in lipid peroxidation and a decrease in antioxidant enzyme superoxide dismutase was also observed in MW exposed group. However, these alterations were reduced significantly when MNP* was administered. Thus, MNP* showed biocompatibility and modulatory effects against MW-induced alterations in the haematological system of rats.

5.
Regul Toxicol Pharmacol ; 149: 105612, 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38570022

RESUMO

Chemical equivalence testing can be used to assess the biocompatibility implications of a materials or manufacturing change for a medical device. This testing can provide a relatively facile means to evaluate whether the change may result in additional or different toxicological concerns. However, one of the major challenges in the interpretation of chemical equivalence data is the lack established criteria for determining if two sets of extractables data are effectively equivalent. To address this gap, we propose a two-part approach based upon a relatively simple statistical model. First, the probability of a false positive conclusion, wherein there is an incorrectly perceived increase for a given analyte in the comparator relative to the baseline device, can be reduced to a prescribed level by establishing an appropriate acceptance criterion for the ratio of the observed means. Second, the probability of a false negative conclusion, where an actual increase in a given analyte cannot be discerned from the test results, can be minimized by specifying a limiting value of applicability based on the margin of safety (MoS) of the analyte. This approach provides a quantitative, statistically motivated method to interpret chemical equivalence data, despite the relatively high intrinsic variability and small number of replicates typically associated with a chemical characterization evaluation.

6.
J Pharm Bioallied Sci ; 16(Suppl 1): S681-S683, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38595564

RESUMO

Background: Recent advancements in three-dimensional (3D) printing have introduced novel materials for removable partial dentures (RPD) base fabrication, promising improved mechanical properties, and biocompatibility. Materials and Methods: In this study, three different RPD base materials were evaluated: conventional heat-cured acrylic resin (Control), biocompatible 3D-printed resin (Test Group A), and a novel nanocomposite 3D-printed resin (Test Group B). A total of 30 standardized RPD base specimens (n = 10 per group) were fabricated according to established protocols. Microstructural analysis was performed using scanning electron microscopy (SEM), and the mechanical properties, including flexural strength and modulus, were determined using a universal testing machine. Results: Microstructural analysis revealed distinct differences among the materials. SEM images showed a well-defined and homogeneous microstructure in Test Group B, while Test Group A exhibited fewer voids compared to the Control group. Mechanical testing results indicated that Test Group B had the highest flexural strength (120 ± 5 MPa), followed by Test Group A (90 ± 4 MPa), and the Control group (75 ± 3 MPa). Similarly, Test Group B demonstrated the highest flexural modulus (3.5 ± 0.2 GPa), followed by Test Group A (2.8 ± 0.1 GPa), and the Control group (2.1 ± 0.1 GPa). Conclusion: These findings suggest that 3D-printed RPD base materials, particularly nanocomposite resins, hold promise for improving the overall quality and durability of removable partial dentures.

7.
Spectrochim Acta A Mol Biomol Spectrosc ; 315: 124246, 2024 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-38593540

RESUMO

We created four fluorescent sensors in our work to determine the viscosity of mitochondria. Following screening, the probe Mito-3 was chosen because in contrast to the other three probes, it had a greater fluorescence enhancement, large Stokes shift (113 nm) and had a particular response to viscosity that was unaffected by polarity or biological species. As the viscosity increased from PBS to 90 % glycerol, the fluorescence intensity of probe at 586 nm increased 17-fold. Mito-3 has strong biocompatibility and is able to track changes in cell viscosity in response to nystatin and monensin stimulation. Furthermore, the probe has been successfully applied to detect changes in viscosity caused by nystatin and monensin in zebrafish. Above all, the probe can be applied to the increase in mitochondrial viscosity that accompanies the ferroptosis process. Mito-3 has the potential to help further study the relationship between viscosity and ferroptosis.

8.
Macromol Biosci ; : e2400071, 2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38569562

RESUMO

Engineered nanomaterials are promising in biomedical application. However, insufficient understanding of their biocompatibility at the cellular and organic levels prevents their widely biomedical applications. Metal-organic frameworks (MOFs) have attracted increasing attention in recent years. In this work, zeolitic imidazolate framework-8 (ZIF-8) and polydopamine (PDA)-modified ZIF-8 are chosen as model nanomaterials due to its emergent role in nanomedicine. In vitro, the results demonstrate that the PDA coating greatly alleviates the cytotoxicity of ZIF-8 to RAW264.7, LO2, and HST6, which represent three different cell types in liver organs. Mechanistically, ZIF-8 entering into the cells can greatly induce the reactive oxygen species generation, which subsequently induces cell cycle delay and autophagy, ultimately leads to enhanced cytotoxicity. Further, human umbilical vein endothelial cells model and zebrafish embryos assay also confirm that PDA can compromise the ZIF-8 toxicity significantly. This study reveals that PDA-coated MOFs nanomaterials show great potential in nano-based drug delivery systems .

9.
ACS Sens ; 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38587867

RESUMO

While most of the research in graphene-based materials seeks high electroactive surface area and ion intercalation, here, we show an alternative electrochemical behavior that leverages graphene's potential in biosensing. We report a novel approach to fabricate graphene/polymer nanocomposites with near-record conductivity levels of 45 Ω sq-1 and enhanced biocompatibility. This is realized by laser processing of graphene oxide in a sandwich structure with a thin (100 µm) polyethylene terephthalate film on a textile substrate. Such hybrid materials exhibit high conductivity, low polarization, and stability. In addition, the nanocomposites are highly biocompatible, as evidenced by their low cytotoxicity and good skin adhesion. These results demonstrate the potential of graphene/polymer nanocomposites for smart clothing applications.

10.
J Periodontal Res ; 2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38644743

RESUMO

AIMS: GBR membranes have various surface properties designed to elicit positive responses in regenerative clinical procedures; dental clinicians attempt to employ techniques to prevent the direct interaction of contaminated oral fluids with these biomaterials. However, saliva is uninterruptedly exhibited in oral surgical procedures applying GBR membranes, suggesting a persistent interaction with biomaterials and the surrounding oral tissues. This fundamental study aimed to investigate potential alterations in the physical, chemical, and key biological properties of membranes for guided bone regeneration (GBR) caused by isolated early interaction with human saliva. METHODS: A reproducible step-by-step protocol for collecting and interacting human saliva with membranes was developed. Subsequently, membranes were evaluated for their physicochemical properties, protein quantification, DNA, and 16S rRNA levels viability of two different cell lines at 1 and 7 days, and ALP activity. Non-interacted membranes and pure saliva of donors were applied as controls. RESULTS: Qualitative morphological alterations were noticed; DNA extraction and 16S quantification revealed significantly higher values. Furthermore, the viability of HGF-1 and MC3T3-E1 cells was significantly (p < .05) reduced following saliva interaction with biodegradable membranes. Saliva contamination did not prejudice PTFE membranes significantly in any biological assay. CONCLUSIONS: These outcomes demonstrated a susceptible response of biodegradable membranes to isolated early human saliva interaction, suggesting impairment of structural morphology, reduced viability to HGF-1 and MC3T3-E1, and higher absorption/adherence of DNA/16S rRNA. As a result, clinical oral procedures may need corresponding refinements.

11.
Regul Toxicol Pharmacol ; 149: 105622, 2024 Apr 06.
Artigo em Inglês | MEDLINE | ID: mdl-38588771

RESUMO

Novel medical devices must conform to medical device regulation (MDR) for European market entry. Likewise, chemicals must comply with the Registration, Evaluation, Authorization and Restriction of Chemicals (REACh) regulation. Both pose regulatory challenges for manufacturers, but concordantly provide an approach for transferring data from an already registered device or compound to the one undergoing accreditation. This is called equivalence for medical devices and read-across for chemicals. Although read-across is not explicitly prohibited in the process of medical device accreditation, it is usually not performed due to a lack of guidance and acceptance criteria from the authorities. Nonetheless, a scientifically justified read-across of material-based endpoints, as well as toxicological assessment of chemical aspects, such as extractables and leachables, can prevent failure of MDR device equivalence if data is lacking. Further, read-across, if applied correctly can facilitate the standard MDR conformity assessment. The need for read-across within medical device registration should let authorities to reconsider device accreditation and the formulation of respective guidance documents. Acceptance criteria like in the European Chemicals Agency (ECHA) read-across assessment framework (RAAF) are needed. This can reduce the impact of the MDR and help with keeping high European innovation device rate, beneficial for medical device patients.

12.
Int J Biol Macromol ; 268(Pt 1): 131493, 2024 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-38608983

RESUMO

Chitosan (CTS), has emerged as a highly intriguing biopolymer with widespread applications, drawing significant attention in various fields ranging from medicinal to chemosensing. Key characteristics of chitosan include solubility, biocompatibility, biodegradability and reactivity, making it versatile in numerous sectors. Several derivatives have been documented for their diverse therapeutic properties, such as antibacterial, antifungal, anti-diabetic, anti-inflammatory, anticancer and antioxidant activities. Furthermore, these compounds serve as highly sensitive and selective chemosensor for the detection of various analytes such as heavy metal ions, anions and various other species in agricultural, environmental and biological matrixes. CTS derivatives interacting with these species and give analytical signals. In this review, we embark on an exploration of the latest advancements in CTS-based materials, emphasizing their noteworthy contributions to medicinal chemistry spanning the years from 2021 to 2023. The intrinsic biological and physiological properties of CTS make it an ideal platform for designing materials that interact seamlessly with biological systems. The review also explores the utilization of chitosan-based materials for the development of colorimetric and fluorimetric chemosensors capable of detecting metal ions, anions and various other species, contributing to advancements in environmental monitoring, healthcare diagnostics, and industrial processes.

13.
Front Bioeng Biotechnol ; 12: 1342340, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38567086

RESUMO

Orthopedic implants are the most commonly used fracture fixation devices for facilitating the growth and development of incipient bone and treating bone diseases and defects. However, most orthopedic implants suffer from various drawbacks and complications, including bacterial adhesion, poor cell proliferation, and limited resistance to corrosion. One of the major drawbacks of currently available orthopedic implants is their inadequate osseointegration at the tissue-implant interface. This leads to loosening as a result of immunological rejection, wear debris formation, low mechanical fixation, and implant-related infections. Nanotechnology holds the promise to offer a wide range of innovative technologies for use in translational orthopedic research. Nanomaterials have great potential for use in orthopedic applications due to their exceptional tribological qualities, high resistance to wear and tear, ability to maintain drug release, capacity for osseointegration, and capability to regenerate tissue. Furthermore, nanostructured materials possess the ability to mimic the features and hierarchical structure of native bones. They facilitate cell proliferation, decrease the rate of infection, and prevent biofilm formation, among other diverse functions. The emergence of nanostructured polymers, metals, ceramics, and carbon materials has enabled novel approaches in orthopaedic research. This review provides a concise overview of nanotechnology-based biomaterials utilized in orthopedics, encompassing metallic and nonmetallic nanomaterials. A further overview is provided regarding the biomedical applications of nanotechnology-based biomaterials, including their application in orthopedics for drug delivery systems and bone tissue engineering to facilitate scaffold preparation, surface modification of implantable materials to improve their osteointegration properties, and treatment of musculoskeletal infections. Hence, this review article offers a contemporary overview of the current applications of nanotechnology in orthopedic implants and bone tissue engineering, as well as its prospective future applications.

14.
Dent Mater ; 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38570242

RESUMO

OBJECTIVES: to assess the impact of universal adhesives, cured with single-peak and polywave LEDs, on the metabolic activity and cytokine release of human dental pulp stem cells (hDPSCs). In addition, analyze the degree of conversion (DC) of the adhesives cured with the different LEDs. METHODS: Discs (5 mm diameter, 1 mm thick) were prepared using three universal adhesives: Single Bond Universal (SBU, 3 M ESPE), Optibond Universal (OBU, Kerr), and Zipbond Universal (ZBU, SDI). These discs were cured for 40 s using a single-peak (DeepCure, 3 M ESPE) or a polywave light-emmiting diode (LED) curing unit (Valo Grand, Ultradent). After 24 h, the specimens were placed in 24-well culture plates, each containing 1 mL of culture medium for 24 h. hDPSCs (1.8 ×104) were seeded in 96-well plates and allowed to grow for 24 h. Subsequently, the cells were exposed to the extracts (culture medium containing eluates from the adhesive discs) for an additional 24 h. Cells not exposed to the extracts were used as a control group. The mitochondrial metabolism was assessed using the MTT assay and the cytokine release evaluated through MAGPIX. The degree of conversion of the adhesives was analyzed using FTIR (n = 5). The results were analyzed by ANOVA two-way and Tukey's test. RESULTS: OBU and ZBU eluates caused a statistically significant reduction in mitochondrial metabolism, regardless of the LED used, indicating their cytotoxicity. In contrast, SBU did not significantly affect the MTT results, resembling the control group. A higher release of cytokines IL-1, IL-6, IL-10, and TNF-α were found in association to ZBU. SBU, on the other hand, increased the release of IL-8. OBU did not influenced the cytokine release. SBU presented the higher DC, while OBU and ZBU had similar DC, lower than SBU. SIGNIFICANCE: In conclusion, universal adhesives exhibit toxicity towards hDPSCs, but the extent of toxicity varies depending on the adhesive material. ZBU was associated with increased cytokine release, particularly pro-inflammatory mediators, from hDPSCs. The different LEDs did not influenced the cytotoxicity of the evaluated adhesives.

15.
Int J Mol Sci ; 25(7)2024 Mar 31.
Artigo em Inglês | MEDLINE | ID: mdl-38612734

RESUMO

Being the green gold of the future, cyanobacteria have recently attracted considerable interest worldwide. This study investigates the adaptability and biocompatibility of the cyanobacterial strain Synechococcus sp. PCC 7002 with human dermal cells, focusing on its potential application in biomedical contexts. First, we investigated the adaptability of Synechococcus PCC 7002 bacteria to human cell culture conditions. Next, we evaluated the biocompatibility of cyanobacteria with common dermal cells, like 3T3 fibroblasts and HaCaT keratinocytes. Therefore, cells were directly and indirectly cocultured with the corresponding cells, and we measured metabolic activity (AlamarBlue assay) and proliferation (cell count and PicoGreen assay). The lactate dehydrogenase (LDH) assay was performed to determine the cytotoxic effect of cyanobacteria and their nutrition medium on human dermal cells. The cyanobacteria exhibited exponential growth under conventional human cell culture conditions, with the temperature and medium composition not affecting their viability. In addition, the effect of illumination on the proliferation capacity was investigated, showing a significant impact of light exposure on bacterial growth. The measured oxygen production under hypoxic conditions demonstrated a sufficient oxygen supply for further tissue engineering approaches depending on the number of bacteria. There were no significant adverse effects on human cell viability and growth under coculture conditions, whereas the LDH assay assessed signs of cytotoxicity regarding 3T3 fibroblasts after 2 days of coculturing. These negative effects were dismissed after 4 days. The findings highlight the potential of Synechococcus sp. PCC 7002 for integration into biomedical approaches. We found no cytotoxicity of cyanobacteria on 3T3 fibroblasts and HaCaT keratinocytes, thus paving the way for further in vivo studies to assess long-term effects and systemic reactions.


Assuntos
Synechococcus , Humanos , Bioensaio , Contagem de Células , Técnicas de Cultura de Células , Oxigênio
16.
Regen Biomater ; 11: rbae030, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38605851

RESUMO

Tooth presents an intriguing option as a bone graft due to its compositional similarity to bone. However, the deproteinized human demineralized tooth matrix (dpDTM), developed to overcome the limited availability of autologous tooth grafts, has suboptimal pore size and surface roughness. This study aimed to fabricate a surface-modified dpDTM using acid etching and collagen coating, followed by in vitro evaluation of physicochemical and biological properties. The dpDTM was modified into two protocols: Acid-modified dpDTM (A-dpDTM) and collagen-modified dpDTM (C-dpDTM). Results demonstrated that A-dpDTM and C-dpDTM had increased pore sizes and rougher surfaces compared to dpDTM. Collagen immobilization was evidenced by nitrogen presence exclusively in C-dpDTM. All groups had a Ca/P molar ratio of 1.67 and hydroxyapatite as the sole constituent, with 65-67% crystallinity. Degradation rates significantly increased to 30% and 20% for C-dpDTM and A-dpDTM, respectively, compared to 10% for dpDTM after 120 days. Cumulative collagen release of C-dpDTM on Day 30 was 45.16 µg/ml. Osteoblasts attachment and proliferation were enhanced on all scaffolds, especially C-dpDTM, which displayed the highest proliferation and differentiation rates. In conclusion, surface modified of dpDTM, including A-dpDTM and C-dpDTM, significantly enhances bioactivity by altering surface properties and promoting osteoblast activity, thereby demonstrating promise for bone regeneration applications.

17.
Regen Biomater ; 11: rbae027, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38605854

RESUMO

Poor bone growth remains a challenge for degradable bone implants. Montmorillonite and strontium were selected as the carrier and bone growth promoting elements to prepare strontium-doped montmorillonite coating on Mg-Ca alloy. The surface morphology and composition were characterized by SEM, EDS, XPS, FT-IR and XRD. The hydrogen evolution experiment and electrochemical test results showed that the Mg-Ca alloy coated with Sr-MMT coating possessed optimal corrosion resistance performance. Furthermore, in vitro studies on cell activity, ALP activity, and cell morphology confirmed that Sr-MMT coating had satisfactory biocompatibility, which can significantly avail the proliferation, differentiation, and adhesion of osteoblasts. Moreover, the results of the 90-day implantation experiment in rats indicated that, the preparation of Sr-MMT coating effectively advanced the biocompatibility and bone repair performance of Mg-Ca alloy. In addition, The Osteogenic ability of Sr-MMT coating may be due to the combined effect of the precipitation of Si4+ and Sr2+ in Sr-MMT coating and the dissolution of Mg2+ and Ca2+ during the degradation of Mg-Ca alloy. By using coating technology, this study provides a late-model strategy for biodegradable Mg alloys with good corrosion resistance, biocompatibility. This new material will bring more possibilities in bone repair.

18.
Nanomaterials (Basel) ; 14(7)2024 Apr 07.
Artigo em Inglês | MEDLINE | ID: mdl-38607176

RESUMO

Polyaniline (PANI) constitutes a very propitious conductive polymer utilized in several biomedical, as well as environmental applications, including tissue engineering, catalysis, and photocatalysis, due to its unique properties. In this study, nano-PANI/N-TiO2 and nano-PANI/Ag-TiO2 photocatalytic composites were fabricated via aniline's oxidative polymerization, while the Ag-and N-chemically modified TiO2 nanopowders were synthesized through the sol-gel approach. All produced materials were fully characterized. Through micro-Raman and FT-IR analysis, the co-existence of PANI and chemically modified TiO2 particles was confirmed, while via XRD analysis the composites' average crystallite size was determined as ≈20 nm. The semi-crystal structure of polyaniline exhibits higher photocatalytic efficiency compared to that of other less crystalline forms. The spherical-shaped developed materials are innovative, stable (zeta potential in the range from -26 to -37 mV), and cost-effective, characterized by enhanced photocatalytic efficiency under visible light (energy band gaps ≈ 2 eV), and synthesized with relatively simple methods, with the possibility of recycling and reusing them in potential future applications in industry, in wastewater treatment as well as in biomedicine. Thus, the PANI-encapsulated Ag and N chemically modified TiO2 nanocomposites exhibit high degradation efficiency towards Rhodamine B dye upon visible-light irradiation, presenting simultaneously high biocompatibility in different normal cell lines.

19.
Heliyon ; 10(8): e29145, 2024 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-38628746

RESUMO

The Mongolian medical silver needles often encounter issues of bending, fracturing, and blunting in clinical applications. Similarly, Mongolian warm needles can cause burns on patients due to inaccurate temperature control. In this study, we developed an Ag85Cu15 alloy specifically for acupuncture needles based on material preparation. By incorporating appropriate amounts of Mn and Ti elements, we were able to enhance the mechanical properties and biocompatibility of the acupuncture needles. Compared to commercially available silver needles, this alloy exhibited a significant increase in microhardness up to 210.2 Hv0.2 and an improved tensile strength of 880.2 MPa. Furthermore, we designed a thermoelectric effect-based temperature measurement model for precise control of the warm needle's temperature, enhancing the therapeutic effectiveness of the treatment.

20.
J Biomater Sci Polym Ed ; : 1-22, 2024 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-38652755

RESUMO

Titanium (Ti) implants are widely used in orthopedic and dental applications due to their excellent biocompatibility and mechanical properties. However, bacterial adhesion and subsequent biofilm formation on implant surfaces pose a significant risk of postoperative infections and complications. Conventional surface modifications often lack long-lasting antibacterial efficacy, necessitating the development of novel coatings with enhanced antimicrobial properties. This study aims to develop a novel Ag-TiO2-OTS (Silver-Titanium dioxide-Octadecyltrichlorosilane, ATO) nanocomposite coating, through a chemical plating method. By employing a 'resist-killing-disintegrate' approach, the coating is designed to inhibit bacterial adhesion effectively, and facilitate pollutant removal with lasting effects. Characterization of the coatings was performed using spectroscopy, electron microscopy, and contact angle analysis. Antibacterial efficacy, quantitatively evaluated against E. coli and S. aureus over 168 h, showed a significant reduction in bacterial adhesion by 76.6% and 66.5% respectively, and bacterial removal rates were up to 83.8% and 73.3% in comparison to uncoated Ti-base material. Additionally, antibacterial assays indicated that the ratio of the Lifshitz-van der Waals apolar component to electron donor surface energy components significantly influences bacterial adhesion and removal, underscoring a tunable parameter for optimizing antibacterial surfaces. Biocompatibility assessments with the L929 cell line revealed that the ATO coatings exhibited excellent biocompatibility, with minimal cytotoxicity and no significant impact on cell proliferation or apoptosis. The ATO coatings provided a multi-functionality surface that not only resists bacterial colonization but also possesses self-cleaning capabilities, thereby marking a substantial advancement in the development of antibacterial coatings for medical implants.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA